KPA EtherCAT Master 2 for Windows x64 and x86 released

A new update to KPA EtherCAT Master 2 – version 2.8.2904.0 – is now available for Windows x64 and x86.
As part of our commitment to continuously enhancing the product, this release includes the following improvements since version 2.7.604.0:

  • EEPROM read operation improvement
    RPC EEPROM read operations now return available EEPROM data even if EEPROM access reports CRC, LOAD, or PDI errors. In such cases, the operation completes with the warning status ECAT_S_EEPROM_ACCESS_IGNOR (0x000B) to indicate that the EEPROM data was obtained despite the reported access errors.
  • Owned processor interface
    Added a common lifecycle interface for owned processors. Owned processors can now be processed automatically according to Master Processor and Thread Processor configuration. For more information see API Help (Templates/Thread Processor).
  • 61_SignalGenerator sample
    New sample 61_SignalGenerator has been added to MIP to demonstrate how to generate a set of deterministic test signals.
  • 61_SignalGeneratorProcessTask sample
    New sample 61_SignalGenerator has been added to MIP to demonstrate how to generate a set of deterministic test signals and prepare 61_SignalGeneratorProcessTask.dll to run the corresponding external process task.
  • Individual configuration for each Master instance
    A new API has been introduced to allow overriding the default Master configuration when creating a Master instance. To implement this API use PARAM_MASTER_INI or PARAM_MASTER_INI_ATTACH.
  • Master Redundancy enable separately
    Now Master Redundancy can be enabled/disabled separately for each Master instance in Multimaster configurations via the INI file (master.redundancy.enable).
  • 40_SimplePLC_Integration sample
    A new sample, 40_SimplePLC_Integration, has been added to demonstrate how to integrate an EtherCAT Master extension into an existing PLC cycle. This sample includes PLC and EtherCAT cycle synchronization as well as asynchronous function block execution. The following features are also included in the sample:
    – Demonstration of requesting ID read
    – Automatic module scan
  • Boolean Data Type parsing
    XML parser detects Boolean Data Type according to ETG.2100 v1.0.3, as follow:
    – ‘false’ or ‘0’ means FALSE
    – ‘true’ or ‘1’ means TRUE

Request an Evaluation Version of KPA EtherCAT Master 2

Contact us for more info

If you have any questions, please feel free to contact us

koenig-pa GmbH
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.